Air Handling Units

CRAH product

Delivering the World's Most Energy Efficient and Sustainable Thermal Management Solutions

Bespoke Spectrum Series offers a range of cooling systems providing high efficiency cooling that creates an optimum environment for server performance while lowering your data center PUE.

Built-to-Order Air Handler for New and Replacement Projects

The Custom Air Handling Unit is a built-to-order air handler for 2,500 to 100,000 CFM, with chilled water, hot water, DX, or steam coils and direct-drive EC fan arrays. Each unit is engineered to the project mechanical schedule, with the sections and options the application requires. Thermally broken, double-wall construction limits casing leakage and condensation, and replacement units match the existing footprint and duct connections.

2,500 to 100,000 CFM Airflow

Chilled water, hot water, DX, or steam coils are sized to the conditions in the project mechanical schedule, with face velocity and row depth set for each unit. Send the schedule, or the nameplate and dimensions of the existing unit, and Air2O returns a design datasheet that confirms performance.

  • 2,500 to 100,000 CFM airflow
  • Chilled water, hot water, DX, or steam coils
  • Sensible and total capacity per schedule
  • Face velocity and row depth per project

Low Pressure Drop, Direct-Drive Fans

Coil face area is a design variable on every unit, which allows low face velocity, low air pressure drop, and lower fan energy where operating cost is the priority. Direct-drive EC fan arrays, with motors up to IE5-level efficiency, vary speed with the load and have no belts to maintain.

  • Coil face area set per project
  • EC fan arrays, motors up to IE5-level efficiency
  • Direct drive, no belt losses
  • Optional energy recovery and air-side economizer

Custom Layouts and Replacement Fit

Each unit is assembled from filter, coil, and fan sections in a draw-through or blow-through arrangement and a horizontal, vertical, or stacked layout. Replacement units are built to the existing footprint, duct connections, and structural weight allowance, and knock-down sections go into mechanical rooms where access is restricted.

  • Horizontal, vertical, or stacked layouts
  • Built to the existing footprint and duct connections
  • Phased replacement while the building operates
  • Optional humidification, heating, and sound attenuation

Custom Sequences, Open Protocols

The unit runs on a native BACnet DDC controller with 44 input and output points as standard, expandable to 224, and communicates over BACnet and Modbus without a gateway. Sequences are written for each project, and the points list and sequence of operations are issued with the submittal.

  • Native BACnet DDC controller
  • BACnet/IP or MS/TP, Modbus TCP or RTU
  • 44 I/O points, expandable to 224
  • Live view of running control logic

Thermally Broken, Low-Leakage Casing

A no-through-metal thermal break separates interior and exterior surfaces across the casing, doors, inspection windows, frames, and drain connections, which limits thermal bridging and exterior condensation. In independent laboratory testing, a 4 in. double-wall, foam-injected panel casing achieved leakage Class CL1 as defined in AHRI Standard 1350.

  • No-through-metal thermal break
  • Double-wall, foam-injected panels
  • Up to Class CL1 leakage, 4 in. panels
  • Thermally broken doors and inspection windows

Basis: Casing air leakage class as defined in AHRI Standard 1350, where CL1 is the most stringent class: a maximum of 1 CFM per 100 sq ft of casing at 1 in. w.g. reference pressure. Class CL1 was achieved in independent laboratory testing of a 4 in. panel casing at 8 in. w.g. negative pressure. AHRI certification is not claimed.

Designed for greater performance,
energy efficiency and reliability!

Tailored Precision. We understand that no two data centers are the same. That's why we work closely with you to design and manufacture air handling units that perfectly align with your unique requirements, whether it's a small-scale operation or a massive cloud computing facility.

Energy Efficiency. In a world that's increasingly conscious of its environmental impact, our units are designed with energy efficiency in mind. We help you reduce your carbon footprint while optimizing performance, thus saving on operational costs.

Uncompromised Quality. We use the highest quality materials and cutting-edge technology to build units that are not just efficient but also reliable. Trust in the durability of our systems to safeguard your data center's continuity.

Industry-Leading Expertise. With a team of experts in air handling and data center cooling, we stay at the forefront of industry developments, ensuring that your data center remains ahead of the curve.

Tailored Precision
Energy Efficiency
Uncompromised Quality
Industry-Leading Expertise
Committed To Innovation Sustainability and Energy Efficency